Alternator

  • Construction and working of alternator

    The construction of alternator or synchronous generator is very much similar to the DC machines. In the DC generator, the armature winding is placed in the rotor and the field winding is placed in the stator. This type of construction…

  • EMF equation of alternator

    The emf induced by the alternator or synchronous generator is three-phase alternating in nature. Let us derive the mathematical equation of emf induced in the alternator. Let, Z = number of conductors in series per phase. Z = 2T, where…

  • Armature winding in alternator

    For an alternator, the armature is kept stationary on the stator. The stationary armature has several advantages over rotating armature. The armature winding is placed on the slots of the stator. The armature winding of dc machine is of closed-circuit…

  • Armature reaction in Alternator or Synchronous Generator

    Armature reaction is an important aspect in DC generator and AC synchronous Generator or Alternator. Armature reaction in alternator is defined as the effect of armature flux on the main flux produced by the field poles. An electric machine normally…

  • Alternator on load

    Whenever the load on the alternator is varied, the terminal voltage will also vary. This variation in terminal voltage is mainly due to three reasons: Voltage drop due to armature resistance IRa, the voltage drop due to armature leakage reactance…

  • Voltage Regulation of Alternator

    The voltage regulation of alternator is defined as “the rise in voltage at the terminals, when the load is reduced from full load rated value to zero, speed and field current remaining constant”. With the change in load, there is a…

  • Voltage regulation of Alternator by EMF method

    The voltage regulation of alternator by EMF method involves the EMF quantities of all the armature parameters (armature resistance, Armature leakage reactance, armature reaction). The drop due to armature reaction is not considered, because it does not occur due to…

  • Voltage regulation of Alternator by MMF method

    Voltage regulation of alternator by MMF method requires mmf (which is a product of field current(I) and number of turns(N) of field winding) for two separate purposes. The field mmf (If1) required to induce the rated terminal voltage is obtained…

  • Parallel operation of Alternator

    Parallel operation of alternator is a method of adding an alternator in the existing live system with another alternator. When there is more demand for power to supply the load, there comes the need for an additional generator. So, additional…